HP_OWER 1150 N

High efficiency air-water DC INVERTER heat pump with very high shutting and double refrigerant circuit, R410A refrigerant, fully wired and pre-assembled, designed for heating, cooling and DHW preparation.
Outdoor installation, resistant to atmospheric agents thanks to the hot-dip galvanized sheet and painted, after processing, with polyurethane powders in the oven at 180 °C.

  • “Full inverter” Air-Water heat pump
  • High efficiency, Energy Class A+
    C.O.P. = 3.90
    E.E.R. = 3.65
  • Extraordinary 1:16 modulation ratio to optimize operating consumption
  • Double refrigerant circuit, powered by 6 scroll compressors that ensure reliability and operating safety even in the event of a component failure, avoiding the complete blocking of the machine
  • Possibility to configure up to 7 machines in cascade
  • Sequential defrosting of the circuits to avoid downtime
  • Intelligent electronics that equally shares the operation hours of the compressors, increasing the useful life of the system
  • LN silencing as standard, consisting of soundproofed compressor housing, guarantee of reduced noise emissions
  • Standard antifreeze kit to optimize the operation of the heat pump in unfavorable temperature conditions, consisting of low absorption heating cables with automatic management and pre-wired electrical connection
  • Low energy consumption DC INVERTER fan motors
  • Resistance to atmospheric agents guaranteed by galvanized sheet metal casing and polyurethane painting
  • Air-gas exchanger in copper pipes and aluminium fins. Geometrically designed to have the highest heat exchange and lowest pressure drops
  • Electrical panel board with IP54 protection degree, with dedicated door to facilitate installation and maintenance works
  • Control system to monitor and adapt the performance of the inverter compressor, circulator and fan, together with the INVERTER technology and the on-board sensors
  • HYDRONIC KIT equipped with:
    - Patented high efficiency water-gas, stainless steel plate exchanger for R410A conceived with double refrigerant circuit and single hydraulic circuit.
    - Integrated modulating INVERTER circulator
    - Circulation and protection flow switch
    - Automatic air vent valve, safety valve (6 bar) and fill & drain cock.
  • Integrated system configurator with expansion modules for I / O resources and MODBUS connection port
  • Flow temperatures: up to 57 °C
  • Operating limit outside temperature:
    -15 °C (Heating) + 46 °C (Cooling).

 